4 Wire 24v Underfloor Heating Actuator
(inc VAT)
The thermal actuator monitors the operation of your underfloor heating system by automatically opening and closing the port valve to regulate the room temperature set at the thermostat. It is suitable for mounting on underfloor heating manifolds, thermostatic valve bodies and three-way valves.
The actuator is designed to fit our range of manifolds but can also be mounted on most modern underfloor heating manifolds with an M30 thread.
The robust housing and internal structure ensures longevity and reliable performance for many years without the worry of deterioration or interruption to the operation of your underfloor heating system.
Available in standard 230v and 24v for low voltage systems.
Features:
- Normally closed
- M30 thread
- 3mm stroke length
- 2w power consumption
- 4 wires as standard
- No tools required for fitting
- Silent operation
- Compact design
- CE marked
Mounting onto the manifold
- Remove the isolation cap on the return manifold
- Position the actuator onto the port value
- Tighten the ring nut by hand- do NOT use a spanner or similar tool.
- Connect the electrical wiring to complete.
Function of Normally Closed Version (NC)
- When applying the operating voltage, the expansion system of the actuator will be heated. After passing the dead time a uniform procedure will follow.
- When the voltage supply is cut off, the actuator will automatically close after passing the dead time due to calling of the expansion system.
Note: in case of any functional testing, be aware of the dead time behaviour and take this into consideration. The opening and closing ties will depend upon the ambient temperature.
Technical Data | |
---|---|
Action | ON/OFF |
Power supply | 230v/AC, 25v/DC (+10%/-15%) |
Frequency | 50 – 60 Hz |
Power consumption (normal operation) | 2W |
Peak starting current | 0.20 A x 0.5 sec (230V) 0.25 A x 60 sec (24V) |
Initial opening (NC) time (power ON) 230V | 75s |
Final opening (NC) time (power ON) | 6 mins |
Initial opening (NC) time (power ON) 24V | 3 mins |
Final opening (NC) time (power ON) | 6 mins |
Actuator stroke | max 4.0 mm |
Valve stroke | 3 mm |
Protection class | Ip54 to En60529 |
Electrical Protection class | II |
Safety (contamination level) | 2 |
Cable length | 1m |
Operation temperature limit | 0 to 50°C |
Storage temperature limit | -25 to 60°C |
Fluid temperature limit | Max 110 °C |
Nominal closing force (power OFF) (Closed type) | 100 N (±10%) |
Auxiliary microswitch (4-pole model) | max 700 mA – 250 V ~ (a.c) |
Cover | Pa66 +30 F.V. self estinguished |
Valve connection | Threaded ring nut M30 x 1.5 |
Action
ON/OFF
Power supply
24 / 230 VAC/DC (+10% / -15%)
Frequency
50 ÷ 60 Hz
Power consumption (normal operation)
2W
Peak starting current
0.20 A x 0.5 sec (230V) 0.25 A x 60 sec (24V)
Initial opening (NC) time (power ON) 230V
75 s
Final opening (NC) time (power ON)
6 min
Initial opening (NC) time (power ON) 24V
3 min
Final opening (NC) time (power ON)
6 min
Actuator stroke
max 4.0 mm
Valve stroke
3 mm
Protection class
Ip54 to En60529
Electrical Protection class
II
Safety (contamination level)
2
Cable length *
1m
4-pole x 0.5 mm2
Operation temperature limit
0 to 50°C
Storage temperature limit
-25 to 60°C
Fluid temperature limit
Max 110 °C
Nominal closing force (power OFF) (Closed type)
100 N (±10%)
Auxiliary microswitch (4-pole model)
max 700 mA – 250 V ~ (a.c)
Cover
Pa66 +30 F.V. self estinguished
Valve connection
Threaded ring nut M30x1.5